Back to Top

1
Hi, Guest!

  LOKASI :  Jogja

  AKTIVITAS :  29/09/2021

BAGIKAN :   

Bagikan :
Kontak Kami  
HOTLINE CALL : 0811 250 8699, 081 827 9262 E-mail : depotsafetyindonesia@gmail.com Website : www.depotsafety.co.id

COMMON BASE Hong-Chang 12V

Update Terakhir
:
05 / 12 / 2020
Min. Pembelian
:
1 Unit
Harga
CALL
Bagikan
:
c/o. PT. Citra Total Proteksindo 
Bergerak di bidang Keselamatan dan Kesehatan Kerja [ PJK3 ] Bidang Proteksi Kebakaran. Bidang Kegiatan : Pemasangan dan Perawatan Proteksi Kebakaran meliputi Alat Pemadam Api Ringan (APAR), Instalasi Deteksi Alarm, Hydrant System, Sprinkler System dan System Pemadam Otomatik Integrated.
ALAT PEMADAM API 
Pengecekan, perawatan, servis dan isi ulang, Alat Pemadam Api Kebakaran ( APAR ) dengan berbagai macam merk antara lain : Alat Pemadam Api MAXGUARD, Yamato, Gunnebo, SERVVO, FUHRER, ARINDO, MASKOT, PROTEKTOR, INDOKA, VIKING, PYROMAX, APPRON, ALTEK, PYROSAFE, PYRENE, MAXIMAX, DAFO, CHUBB, FIREGUARD, REVO, VENUS, STARVVO, VULCAN, PRIMA, HARTINDO AF 11, FIROTECT, ALPINDO, GUARDALL, PROTECT, dll.
Dengan segala jenis media racun api yang digunakan, seperti : ABC DRY CHEMICAL POWDER, BC POWDER, GAS CAIR HALON FREE, HCF 21, HCFC 123, R141B GAS, HALOTRON 1, NAF P IV, SOFKAFLAM, CARBON DIOXIDE CO2, BUSA AB, FAOM LIQUID, FOAM AFFF 3%, FOAM AFFF 6%, VULCAN AF 21, VULCAN AF 31 (WATER BASED), VULCAN AF 11, MAXGUARD AF 11, dll. 
Dengan berbagai type, seperti : Portable, Trolly ( Pakai Roda) & Thermatic System, dengan harga yang kompetitif, ekonomis, bergaransi dan jaminan kualitas yang baik sesuai kebutuhan anda, melayani antar jemput atau layanan ditempat Anda.
FIRE ALARM SYSTEM
Jasa Pemasangan Baru Instalasi Fire Alarm System dan Jasa Pengecekan Teknis, Perawatan (Maintenance) Fire Alarm System, dengan berbagai macam merk antara lain : Fire Alarm System MAXGUARD, Fire Alarm APPRON, Fire Alarm APOLLO, Fire Alarm HOOSEKI, Fire Alarm HONG CHANG, Fire Alarm KIDDE SERIES, Fire Alarm ESSER, Fire Alarm HONEYWELL, Fire Alarm NOTIFIER, Fire Alarm HOCHIKI, Fire Alarm NOHMI, Fire Alarm SIMPLEX, Fire Alarm PROTEKTOR, Fire Alarm NITTAN, Fire Alarm System EDWARD, Fire Alarm SIEMENS, Fire Alarm GST, Fire Alarm YUN YANG, Fire Alarm HORING LIH, Fire Alarm TELEFIRE, dll.
FIRE HYDRANT SYSTEM
Jasa Pemasangan Baru Instalasi Fire Hydrant System dan Jasa Pengecekan Teknis, Perawatan (Maintenance) Fire Hydrant System, dengan berbagai macam merk antara lain : Fire Hydrant System MAXGUARD, Fire Hydrant APPRON, Fire Hydrant VENUS, Fire Hydrant X-FIRE, Fire Hydrant HOOSEKI, Fire Hydrant YAMATO, Fire Hydrant GUNNEBO, Fire Hydrant PROTECTOR, Fire Hydrant ZEKI, Fire Hydrant OZEKI, Fire Hydrant ALPINDO, Fire Hydrant FIROTECT, dll.
FIRE SPRINKLER SYSTEM
Jasa Pemasangan Baru Instalasi Fire Sprinkler System dan Jasa Pengecekan Teknis, Perawatan (Maintenance) Fire Sprinkler System, dengan berbagai macam merk antara lain : Fire Sprinkler System MAXGUARD, Fire Sprinkler APPRON, Fire Sprinkler VENUS, Fire Sprinkler X-FIRE, Fire Sprinkler HOOSEKI, Fire Sprinkler YAMATO, Fire Sprinkler GUNNEBO, Fire Hydrant PROTECTOR, Fire Sprinkler FIROTECT, Fire Sprinkler TYCO, Fire Sprinkler SHILLA, Fire Sprinkler NATIONAL, Fire Sprinkler VIKING, dll.
FIRE INSTALATION SYSTEM

Detail COMMON BASE Hong-Chang 12V

COMMON BASE Hong-Chang Description on the linkage of base and detector The design of the base is for one-way barrier-free installation. As the detector turns to the linking place in a clockwise direction, do not apply any thrust. Just let it get in the linking place automatically, When it reaches the fixed point, the turning act is completed. Descriptions on the functions of detector 1. Functions of detection0 When the detector is at a normal and ready situation, the LED flashes once every 4 ~ 6 seconds. In times of abnormal situation, such as the return circuit being cut or the detector malfunctioned and not working, ask the maintenance staff to observe the conditions of the detector visually. 2. Moveable alarm function of entrance light0 Within a region ( or in an apartment of a building) , install more than one detector with the function of R-end wiring. Connect either the R-end or the L-end of wire to a place( e.g. the entrance) that can be distinguished easily, and then install an LED. When the detector functions, the LED at the entrance will be turned on at the same time. It is good for the maintenance staff. Who can identify the location of the function region easily ( or it can be the source of signal) . Main component material. Mainframe ABS/ PA765 Ivory. Terminal plate Stainless steel plate. Terminal screw Iron ( nickel-plated) Accessories ABS/ PA765 Ivory Screw nut Iron ( nickel-plated) COMMON BASE | HC-202D | HC-206A | HC-207D | HC-306A | HC-307D | HC-406 | HC-407A | HC-407D | HC-601UV
heat detector
Tampilkan Lebih Banyak
depot safety
depot safety

DEPOT SAFETY

PREMIUM GOLD 15 Tahun
Jl. Sugeng Jeroni No. 72 Yogyakarta, Jogja
Indonesia 55251
Jogja
29 / 09 / 2021
Hubungi Kami

Detail COMMON BASE Hong-Chang 12V

COMMON BASE Hong-Chang Description on the linkage of base and detector The design of the base is for one-way barrier-free installation. As the detector turns to the linking place in a clockwise direction, do not apply any thrust. Just let it get in the linking place automatically, When it reaches the fixed point, the turning act is completed. Descriptions on the functions of detector 1. Functions of detection0 When the detector is at a normal and ready situation, the LED flashes once every 4 ~ 6 seconds. In times of abnormal situation, such as the return circuit being cut or the detector malfunctioned and not working, ask the maintenance staff to observe the conditions of the detector visually. 2. Moveable alarm function of entrance light0 Within a region ( or in an apartment of a building) , install more than one detector with the function of R-end wiring. Connect either the R-end or the L-end of wire to a place( e.g. the entrance) that can be distinguished easily, and then install an LED. When the detector functions, the LED at the entrance will be turned on at the same time. It is good for the maintenance staff. Who can identify the location of the function region easily ( or it can be the source of signal) . Main component material. Mainframe ABS/ PA765 Ivory. Terminal plate Stainless steel plate. Terminal screw Iron ( nickel-plated) Accessories ABS/ PA765 Ivory Screw nut Iron ( nickel-plated) COMMON BASE | HC-202D | HC-206A | HC-207D | HC-306A | HC-307D | HC-406 | HC-407A | HC-407D | HC-601UV
heat detector
Tampilkan Lebih Banyak